Buying Guide

Moisture Analyzers: How Loss-on-Drying Works and How to Get Repeatable Results

By Ramo Trading 3 min read

Key takeaways
  • A moisture analyzer is a balance plus a heater. It weighs the sample, dries it and calculates moisture from the weight lost.
  • Results usually take 5–15 minutes, compared with hours in a drying oven.
  • Repeatable results depend on sample size, spreading, temperature and switch-off criteria, not just the instrument.

How loss-on-drying works

The analyzer records the starting weight, heats the sample with a halogen or infrared heater, and keeps weighing as moisture evaporates. When the weight stops changing (the switch-off criterion), it reports moisture content as % moisture, % solids or ratio. Anything that evaporates at the drying temperature counts as "moisture", so the method must be validated for each product.

Where moisture analyzers are used

Industry Typical samples
Food & agriculture Flour, grains, dairy powders, snacks, coffee, animal feed
Plastics Resin pellets before molding, to prevent defects
Pharmaceuticals Granulates, excipients and powders during drying steps
Chemicals & materials Pigments, adhesives, sludge, minerals, textiles

Our moisture analyzers

Settings that make or break repeatability

  1. Sample size: use enough sample to be representative (often 2–10 g), and use the same amount every time.
  2. Spread it evenly in a thin layer on the pan. Clumps dry unevenly and give low results.
  3. Drying temperature: high enough to drive off water quickly, but low enough not to burn or decompose the sample. Start from the oven method you're replacing and adjust.
  4. Switch-off criterion: end the test when weight loss per time falls below a set value, or after a fixed time. Use the same setting for every test.
  5. Use glass-fiber pads for liquids, pastes and samples that form a skin. They spread the sample and speed up drying.

Choosing a model

  • Readability: 1 mg is typical. Choose 0.1 mg for low-moisture samples.
  • Maximum temperature and halogen vs. infrared heating
  • Stored methods, if you test several products
  • Data output (USB, printer, LIMS) for traceability
  • Verification tools: temperature calibration kits and test weights

Frequently asked questions

Will my moisture analyzer match the oven method?

It can, once you adjust temperature and switch-off settings to correlate with the reference method. Run both methods side by side on several samples while validating.

Why are my results lower than expected?

The usual causes are samples that are too thick or clumped, a temperature that is too low, or a switch-off that comes too early. Sample handling before the test (moisture loss or pickup) also matters.

Need help choosing a moisture analyzer?

Send us your sample type and expected moisture range, and we'll recommend a model and settings.

Request a Quote

Shop: Moisture Analyzers · OHAUS · Radwag · Read next: Balance Calibration Made Simple

Comments (0)

Comments are reviewed before they're published.

Related articles