SUBSCRIBE TO OUR NEWSLETTER
Register now to get updates on promotions and coupons.
Estimated Delivery
Mar 09 - Mar 16
لم نتمكن من تحميل توفر الاستلام
Free standard shipping on orders over $99
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).
If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
BUCK Scientific 10 Port Gas Sample Valve, Electric Actuator
Note: For all International Orders, the buyer will be solely responsible for the customs clearance, duty, and taxes imposed on the package.
Buck uses 10 port gas sampling valves because they provide more analytical flexibility for the same cost as four or six port valves. 10 port gas sampling valves can easily be plumbed to replicate the function of the simpler valves, while offering many other possible configurations, including: Inject Only, Inject and Backflush, Pre-column Backflush to Vent, Column Sequence Reversal, Alternate Loop Inject, and Dual Loop-Dual Column. Many more plumbing configurations are possible, especially when multiple valves are plumbed together.
The heated valve oven can be adjusted from ambient to 175 degree C (up to 300 degree C for a manual valve). It mounts on the 910 GC, and can accommodate two electrically actuated and one manually operated valve. Because the valve oven is right next to the column oven, tubing runs are short with no cold spots, which results in sharper peaks.
|
|
Shown above are dual 10-port gas sampling valves in the heated valve oven of a dual TO-14 Air Concentrator. |
Shown above is a 22-port stream selector valve on our 10 position Purge & Trap Autosampler. |
10-port Manually actuated valve, plumbed & tested* |
Automated 22-port, 10-stream selection valve, stand-alone, plumbed & tested |
Each valve includes 1/8" stainless steel bulkhead fittings on the front of the valve oven for sample in/out connections. A single heated (375 degree C max) fast-cooling adsorbent trap plumbed as the loop of the gas sampling valve is also available for applications where sample concentration is desired. The trap cools to a user-controlled setpoint, not just to ambient temperature, so the adsorbent characteristics (water rejection, etc.) can be manipulated.
The valve plumbing configuration shown at right is the standard 6-port configuration. The sample loop is inserted into the carrier gas stream when the valve is rotated to the INJECT position. | |
The same 10-port valve can also be configured to backflush the column when the valve is rotated. Backflushing can often shorten the analysis by eliminating the need to program the column temperature up to elute high boiling analytes. | |
A single 10-port valve can be plumbed to inject the same sample onto two separate loops. This is especially useful when two different carrier gas types are used, or when the detectors employed have very different sensitivities and need different sample sizes injected. | |
The 10-port valve configuration shown at right is our Multiple Gas Analyzer #1 (MG#1) valve. In the LOAD position, the sample loop is filled with fresh sample gas, and the Silica Gel column is downstream of the MoleSieve column. When the valve is rotated into the INJECT position (shown), the contents of the loop are flushed into the Silica Gel column, which is now upstream. The lightest analytes blow through onto the MoleSieve column for separation. The valve is then rotated back to the LOAD position, just prior to the elution of ethane, for the separation of C2-C6. Thermostatted valve oven, mounted on a 910C GC |